System Integration Questions

Question Asked:

I am looking for equipment and expertise to track the position of a .2 mm dia fluorescent particle in clear fluid contained in a dark 150 mm cubic volume. Will want hardware with software and integrator to interface with display to show track of particle.

3 Answers

  • = Company Profile
  • = Answered Questions

Rex Lee - CEO/President
Pyramid Imaging, Inc.
dr [dot] lee [at] pyramidimaging.com
(813) 984-0125

Hi Clark, We should be able to help you on this project. However, there are numerous questions that we need answered to determine all the constraints that may impede a successful conclusion. Can you please send me your contact info and I'll be happy to begin a data exchange with you? Send to Dr.Lee@pyramidimaging.com

Andy Long - CEO
Cyth Systems, Inc.
andy [dot] long [at] cyth.com
888-508-7355

Clark, This looks like quite an exciting project. We have done similar things in the past. There are a number of questions that you will need to answer and I'll list some of them here to allow others in a similar position to be able to look it up. - What frequency of light are you suing to stimulate the particle? - What frequency of light does the particle fluoresce at? I'm assuming a Stoke's shift. - Does the whole 0.2mm diameter particle fluoresce.? - Are you interested in measuring the particle in x,y and z? - How fast does the particle move? - What is the material of the box? Hope these questions help? Feel free to give me a call or email with additional questions. A.

Mark Rothmund - Project Manager
Carl Zeiss Automated Inspection GmbH
mark [dot] rothmund [at] zeiss.com
49 7941 91 00 0

With our systems it is not possible to measure the position of an item in this big range (+/- 75 mm).